UV SERIES Vacuum Pumps

UV SERIES
Vacuum Pumps

Air-cooled

Single-stage

Rotary Vane
Vacuum Pumps

UV SERIES CATALOG UV SERIES CATALOG (imperial) TECHNICAL DATA CONTACT US

Pneumofore’s legendary UV Series models currently installed in industrial plants worldwide evacuate a monstruous billion+ m3 each year.

And not only more reliably, but also more efficiently than any other vacuum pump. These pumps cover a wide vacuum range and offer single stage 250 to 7.160 m3/h [148 to 4.211 cfm] with the residual pressure of 0,5 to 450 mbar(a) [29,90 to 16,62 inHg V]. Capacity and residual pressure are extended with multiple stage machines. The family of UV pumps includes several versions, described below, for a wide variety of applications.

Suction volumes from 250 m3/h to 7.160 m3/h (Single stage). 99,95% maximum vacuum degree [0,5 mbar(a) residual absolute pressure] with performance curves constant up to 95%.

Reduced electric energy consumption when compared to liquid ring pumps with same nominal capacity. Up to 70% savings on replacements.

“Plug and play” pumps, easy to install and integrate.

Air cooling through an aluminium radiator and a temperature controlled fan. Water-free cooling prevents problems related to limestone, ambient temperature and unstable vacuum degree.

Special aluminum alloy vanes provide active sealing, avoiding efficiency loss and minimizing cost of operation and maintenance.

“Closed-loop” lubrication circuit ensures negligible coolant consumption.

TECHNICAL DATA
Select a model
Select a model and swipe to the left for more data

Pressure Range
Capacity
Nominal Power
Absorbed Power*
Dimensions
Noise
Weight
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
L x W x H
50 Hz
60 Hz
kg
mbar(a)
m3/h
kW
kW
mm
db(A)
100 5.389 6.359 2×75 2×90 96,6 126,8 4.180 78 79 5.500
200 5.546 6.544 2×75 2×90 106,0 140,5 1.080 78 79 5.500
300 5.552 6.552 2×75 2×90 117,0 152,1 2.150 78 79 5.500

Imperial Units

Pressure Range
Capacity
Nominal Power
Absorbed Power*
Dimensions
Noise
Weight
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
L x W x H
50 Hz
60 Hz
lbs
PSI(a)
cfm
HP
HP
inch
db(A)
1,45 3.172 3.740 2×100 2×125 129,4 170,0 165 78 79 12.125
2,9 3.264 3.849 2×100 2×125 142,0 188,4 42 78 79 12.125
4,35 3.268 3.854 2×100 2×125 156,8 203,9 79 78 79 12.125
Pressure Range
Capacity
Nominal Power
Absorbed Power*
Dimensions
Noise
Weight
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
L x W x H
50 Hz
60 Hz
kg
mbar(a)
m3/h
kW
kW
mm
db(A)
100 2.694 3.179 75 90 48,3 63,4 2.670 78 79 2.850
200 2.773 3.272 75 90 53,0 70,3 1.280 78 79 2.850
300 2.776 3.276 75 90 58,5 76,0 2.000 78 79 2.850

Imperial Units

Pressure Range
Capacity
Nominal Power
Absorbed Power*
Dimensions
Noise
Weight
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
L x W x H
50 Hz
60 Hz
lbs
PSI(a)
cfm
HP
HP
inch
db(A)
1,45 1.586 1.870 100 125 64,7 85,0 105 78 79 6.283
2,9 1.632 1.924 100 125 71,0 94,2 51 78 79 6.283
4,35 1.634 1.927 100 125 78,4 102,0 87 78 79 6.283
Pressure Range
Capacity
Nominal Power
Absorbed Power*
Dimensions
Noise
Weight
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
L x W x H
50 Hz
60 Hz
kg
mbar(a)
m3/h
kW
kW
mm
db(A)
100 1.759 2.076 45 55 34,4 45,3 2.270 74 75 1.800
200 1.801 2.125 45 55 37,3 47,8 1.450 74 75 1.800
300 1.806 2.132 45 55 39,5 50,0 2.050 74 75 1.800

Imperial Units

Pressure Range
Capacity
Nominal Power
Absorbed Power*
Dimensions
Noise
Weight
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
L x W x H
50 Hz
60 Hz
lbs
PSI(a)
cfm
HP
HP
inch
db(A)
1,45 1.035 1.221 60 75 46,1 60,7 90 74 75 3.968
2,9 1.060 1.250 60 75 50,0 64,1 57 74 75 3.968
4,35 1.063 1.254 60 75 52,9 67,0 81 74 75 3.968
Pressure Range
Capacity
Nominal Power
Absorbed Power*
Dimensions
Noise
Weight
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
L x W x H
50 Hz
60 Hz
kg
mbar(a)
m3/h
kW
kW
mm
db(A)
100 1.301 1.534 30 37 24,0 31,4 1.925 73 74 1.570
200 1.323 1.569 30 37 26,2 34,5 1.500 73 74 1.570
300 1.325 1.571 30 37 28,1 37,0 1.800 73 74 1.570

Imperial Units

Pressure Range
Capacity
Nominal Power
Absorbed Power*
Dimensions
Noise
Weight
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
L x W x H
50 Hz
60 Hz
lbs
PSI(a)
cfm
HP
HP
inch
db(A)
1,45 765 902 40 50 32,2 42,1 76 73 74 3.461
2,9 779 922 40 50 35,1 46,2 59 73 74 3.461
4,35 780 924 40 50 37,7 49,6 71 73 74 3.461
Pressure Range
Capacity
Nominal Power
Absorbed Power*
Dimensions
Noise
Weight
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
L x W x H
50 Hz
60 Hz
kg
mbar(a)
m3/h
kW
kW
mm
db(A)
100 969 1.143 22 30 16,2 20,9 1.385 69 70 1.070
200 998 1.177 22 30 18,8 23,9 1.280 69 70 1.070
300 1.000 1.179 22 30 20,2 25,7 2.180 69 70 1.070

Imperial Units

Pressure Range
Capacity
Nominal Power
Absorbed Power*
Dimensions
Noise
Weight
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
L x W x H
50 Hz
60 Hz
lbs
PSI(a)
cfm
HP
HP
inch
db(A)
1,45 570 672 30 40 21,7 28,0 55 69 70 2.360
2,9 587 692 30 40 25,2 32,0 51 69 70 2.360
4,35 589 693 30 40 27,1 34,5 86 69 70 2.360
Pressure Range
Capacity
Nominal Power
Absorbed Power*
Dimensions
Noise
Weight
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
L x W x H
50 Hz
60 Hz
kg
mbar(a)
m3/h
kW
kW
mm
db(A)
100 409 490 11 15 9,0 10,8 1.600 68 69 670
200 410 492 11 15 9,5 11,4 680 68 69 670
300 430 516 11 15 9,9 11,9 1.775 68 69 670

Imperial Units

Pressure Range
Capacity
Nominal Power
Absorbed Power*
Dimensions
Noise
Weight
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
L x W x H
50 Hz
60 Hz
lbs
PSI(a)
cfm
HP
HP
inch
db(A)
1,45 241 288 15 20 12,1 14,4 63 68 69 1.477
2,9 242 289 15 20 12,7 15,2 27 68 69 1.477
4,35 253 303 15 20 13,3 15,9 70 68 69 1.477
Pressure Range
Capacity
Nominal Power
Absorbed Power*
Dimensions
Noise
Weight
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
L x W x H
50 Hz
60 Hz
kg
mbar(a)
m3/h
kW
kW
mm
db(A)
100 220 264 5,5 7,5 4,9 5,9 825 67 68 290
200 225 270 5,5 7,5 5,1 6,1 915 67 68 290
300 235 282 5,5 7,5 5,3 6,4 1.170 67 68 290

Imperial Units

Pressure Range
Capacity
Nominal Power
Absorbed Power*
Dimensions
Noise
Weight
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
L x W x H
50 Hz
60 Hz
lbs
PSI(a)
cfm
HP
HP
inch
db(A)
1,45 129 155 7,5 10 6,6 8,0 33 67 68 441
2,9 132 159 7,5 10 6,8 8,3 36 67 68 441
4,35 138 166 7,5 10 7,1 8,7 46 67 68 441

Hz = frequency
m3/h = air capacity at the rated pressure
* = total machine absorbed power with class IE3 efficiency electric motors, all auxiliares included.
Standard reference atmosphere conforms to ISO 8778: 1 bar(g), 20°C, 65% relative humidity

ADAPTED VERSIONS

UV – THE CORE SERIES: Models from UV4 to UV100 with a capacity range of 250 to 7.160 m3/h and up to 0,5 mbar(a) residual pressure. All components on board, ready-to-go.

UV H – Water vapor suction capability, machine temperature 110° C [230° F] for drying processes. Unique feature, exclusively by Pneumofore.

UV HC – Hot climate version of air cooled pumps for ambient temperature up to 55° C [131° F]. Extra large heat exchangers and fans for tropical climates.

UV VS – Variable speed drive from 30 to 65 Hz to optimize the power consumption, for a constant vacuum at the process.

UV W – Water-cooled version for installation in closed areas or for heat recovery purposes.

UV Ex – Explosion-proof. Installation in explosive areas with dedicated electrical components.

UV B – Double stage vacuum system with a roots blower as second vacuum stage. Can be combined with any other UV version. Frequently applied in pipeline drying.

UV HR – Heat Recovery vacuum system for room temperature above 40°C.

UV S – Special versions of UV pumps for tailored dimensions, ethernet, skid mounted, stainless steel, weather proof construction or extra heavy duty frame.

UV SERIES IN ACTION