When the bathroom faucet is dripping, usually a little twist of the handle to tighten the internals will stop it. When a mechanical seal is leaking, however, over-tightening the fasteners can make the situation worse.
To properlyinstall a mechanical seal, consider the following precautions:
Overtightening puts undue stress on the mechanical seal internals. This sets the seal up for failure from mechanical shock. Mechanical shock is caused by bad bearings, cavitation, excessive torque, uneven loading, and misaligned shafts. Mechanical shock commonly occurs due to mishandling and improper assembly of the seal.
Overtightening also can compress the springs and add additional loading forces on the seal faces. This causes the seal to run hotter than it should, and most likely wear sooner than expected.
When mechanical seal fasteners are overtightened, the stationary seal components become distorted, gaskets can be damaged or extruded, all resulting in leakage.
If a mechanical seal is leaking, restrain yourself from the natural tendency to tighten, and try loosening instead. Oftentimes this works.
Check the installation manual for guidance on just how tight to fasten those bolts. Consider employing a torque wrench to ensure accuracy.
If leaking persists after ensuring proper torque on the fasteners, consider getting a mechanical seal expert involved. They may be able to save you a lot of time and frustration troubleshooting the seal.
Got a mechanical seal question? Ask us about it!We gladly provide technical assistance to businesses and municipalities in Wisconsin and upper Michigan.
These Stories on Mechanical Seals
Headquarters and Service Center
707 Ford Street
Kimberly, WI 54136
920-733-4425
OptiFlow Design and Build Center
1002 Truman Street
Kimberly, WI 54136
920-733-4425
Service Center
12265 Nicollet Avenue
Burnsville, MN 55337
800-776-4425
Service Center
26489 Industrial Blvd
Cohasset, MN 55721
800-776-4425
© Copyright 2020. Crane Engineering. All Rights Reserved. Privacy Policy.